Each service stands on its own, and together they deliver integrated systems that perform beyond the sum of their parts.

Thermal Energy Storage

Shift cooling load to off-peak hours with stratified chilled-water and buffer tanks engineered to hold their temperature difference.

  • Stratified CHW and buffer tank design
  • Diffuser and inlet geometry optimisation
  • CFD-validated thermocline performance

Large District Cooling Plants

Central plant design and optimisation for campuses, townships and mixed-use developments where reliability is non-negotiable.

  • Chiller plant configuration and sequencing
  • Capacity planning and redundancy strategy
  • Energy and lifecycle cost modelling

Large-Scale CHW Networks

Hydraulic design and balancing for chilled-water distribution networks that keep delta-T high and pumping energy low.

Large CHW Systems Controls

Control strategies and BMS integration that turn complex chilled-water systems into predictable, efficient assets.

  • Plant control philosophy and sequences
  • BMS integration and commissioning
  • Real-time monitoring dashboards

Flow Control & Synchronisation

Matching production to demand across chillers, pumps and terminal units to eliminate bypass, short-circuiting and waste.

  • Variable primary flow strategies
  • Pump and valve synchronisation
  • Bypass and short-circuit elimination

In-Building System Optimisation

Audit-led retrofits that recover efficiency inside the building, from AHUs and FCUs to secondary loops.

  • Energy audits and ESCO projects
  • HVAC retrofit design
  • Measurement & verification reporting
Supporting services

Beyond design.

Services that help clients operate, report and continuously improve long after handover.

Digital Dashboards

Live performance visibility for plant operators and management.

BMS Integration

Connecting plant equipment, sensors and controls into one platform.

Energy Compliance

Audits, reports and documentation aligned with regulatory requirements.

Client Support

Ongoing engineering support and reporting templates for your team.

HVAC chilled water pumps
Proven in practice

See how simulation transforms thermal storage.

Our CFD buffer tank study shows how geometry, diffuser design and inlet orientation determine whether a tank holds its thermocline, or wastes energy.

Read the case study

Let’s unlock your next efficiency gain.